1. How to manage fine dust
T2PM is capable of Cloud Serivce monitoring and RS-485 output.
Do you scan the QR code when entering a restaurant anytime, anywhere?
Just swipe the QR code like that.
We create a remote monitoring system so that that is the site.
By investing only the cost of a one-year subscription to Millie's study, you can start monitoring the Cloud Serivce right away.
As it is the facility equipment currently in use,
Do you need integrated RS-485 management that only adds and manages fine dust sensors?
T2PM, which transmits real-time fine dust data, supports both Cloud Serivce and RS-485.
If you have decided how to manage fine dust, start now.

2. Fine dust Class 10000
If our workplace is Class 10000, there is no better answer than T2PM.
10000 class workplace, already in use by many automotive electronics companies.
No more cumbersome, hands-on work.
You can compare fine dust data by job site and 8 graphs at a glance.
In addition, daily/weekly/monthly reports are automatically sent to the person in charge.

3. Fine dust alarm
It's not an alarm that goes off every now and then.
Exceptions are skipped, and essential alarms are sent in multiple languages of field workers.
If the appropriate management level is exceeded, the device's buzzer alarm and cell phone call alarm notify you of the problem in real time.
Phone alarms and text alarms are sent in the field worker's language .
It's an alarm when it's really urgent.
Various alarm exception settings are also provided, such as ignoring a specific time when a set action is performed, or ignoring duplicate detection for a set period of time.

4. Fine dust management standards
Please set appropriate management standards in T2PM.
You will be notified by a smartphone, electronic signboard, or a warning light.
Equipped with a laser scattering type fine dust sensor, T2PM detects PM2.5 as a basic function, and
It measures fine dust of various sizes from PM0.5 to PM10.0 .
The measurement method can also be selected as a desired type from among the cumulative method and the range range method.

* Data source: Comprehensive measures for fine dust in the Korean policy briefing

5. How to read fine dust
T2PM allows you to choose any unit of measure you want.
The default unit of measurement for T2PM is ug/m³.
As with the default value, fine dust can be measured by weight, or as the number of particles per cubic centimeter such as #/cm³.
It can measure fine dust.
In other words, fine dust can be managed in both weight and quantity units.
Q. If the channel 1 (CH1) value is confirmed to be 28.80 ug/m³, what does this mean?
A. This means that the cumulative number of particles ranging in size from 0.3 µm to 2.5 µm per cubic meter is 25.80 .

* PM0.5, which is ultrafine dust, is output in quantity unit #/cm3 even if ug/cm3 is selected.
* Source: Korea Policy Briefing Comprehensive Countermeasures against Fine Dust
-
PREV News Letter V.2103
-
NEXT News Letter V.2105