NEWS LETTER V.18071
We bring you the news of Radionode, a brand specializing in sensor data remote monitoring system.
Introducing the UA52, which can also measure atmospheric pressure.
For a more complete system alarm, Blackout Alarm Beta has been released.
Temperature management introduces the basic, door opening function of RN400.
이Just add Radionode, a working monitoring device that sends only the alarms I really need.
mBar Measure atmospheric pressure with UA52
"Do you know the UA52, an oxygen sensor with an atmospheric pressure sensor?"
"1 Atm = 760 mmHg = 1013.25 mBar"

Why do my knees hurt when it rains? Why do my ears get numb when climbing a mountain or changing altitude in an airplane?
Developed as an optical oxygen sensor UA52On atmospheric pressure sensor와 temperature Senseris built-in to measure and transmit current oxygen (%, ppm, mBar), atmospheric pressure (mBar, mmH2O), and temperature (℃, ℉) data in real time.
It is equipped with an ultra-precise atmospheric pressure sensor with a resolution of 1mBar and an accuracy specification of ±5mBar, enabling precise environmental measurement.
In addition, offset correction is possible by using the UA calibrator for gas sensors. Therefore, it can be used with confidence in the gas industry, aerospace business, and smart building solution companies.
As with existing UA products, it is recognized as a Serial COM port by the computer, so it is controlled through AT commands.
Sensor data can be efficiently managed on a smartphone or PC through the monitoring software Tapaculo (Lite/Mobile/365) that has received the data.
* Measurement mode
- Mode 1: Oxygen [%], Temperature [°C/°F]
- Mode 2: Oxygen [mBar], atmospheric pressure [mBar]
- Mode 3: Oxygen [ppm], atmospheric pressure [mmH2O]
- Mode 4: Oxygen [%], atmospheric pressure [mBar]
If you have more questions about the UA52, please contact master@dekist.com.
Tapaculo365 Launches Power Loss Alarm Beta
"A more perfect system alarm with the addition of a power outage alarm function"
"Able to respond to emergencies faster"

The function of Tapaculo 365 has been updated. Different from the existing communication disconnection alarm blackout alarm System alarms are more complete with the introduction of the feature.
The existing communication disconnection alarm is an alarm that occurs when data is not transmitted during the data transmission period, and it is impossible to distinguish whether it is a power outage alarm or a communication network disconnection situation.
But the power outage alarm Distinguish whether the current state of power outage or communication network is disconnectedyou can do it take action faster It allows you to take it.
How does a power outage alarm work? If a power outage occurs at the site while using the RN400 product while supplying power with DC power, the RN400 will automatically supply power from the battery.
If it recognizes this power supply method and communicates the power outage through Wi-Fi, it notifies registered users of the power outage by sms or email.
When the power is turned back on by the action of the user who has been notified, a message is sent saying "DC power supply has resumed", and the power outage situation is ended.
* Setting path: Device settings > New power outage alarm button
* Available from Yellow members
Thermometer for material warehouse that can detect door opening
"Real-time notification of temperature, humidity, and door open detection"
"RN400, from door open detection to notification sending in 5 seconds"

Industrial thermo-hygrometer, Radionode RN400, not only temperature and humidity monitoring, which was the basic function of previously released products, but also contact control and door open detection A function was also added.
RN400In addition, the sensor is used in conjunction with EX model, there is a terminal to which the door sensor can be connected.
When the door sensor is connected to the corresponding terminal, the door open detection function is activated, and when the door is opened, a notification message is sent to the registered person in 5 seconds.
As with existing alarms, it is possible to set an alarm detection exception so that an alarm does not occur during normal operation by setting the overlap detection waiting time, first detection ignore period, and detection exception time.
Set door open alarms in necessary places such as freezers, material warehouses, logistics warehouses, and garages, and live with peace of mind.
-