Radionode UA20-D, reduce maintenance costs with power monitoring!
Radionode has released a new Pulse counter, ProductsUA20-D. Get started with Radionode's solution that provides visual power monitoring.
You can carry out energy management tasks that have been vague for a while and improve work efficiency.
Radionode power monitoring system

equipment needed
To start monitoring wattage you will need the following equipment:
● RN171(PoE) 또는 RN172(WiFi)
● UA20-D (New ProductsPulse counter)
Benefits of Radionode Power Monitoring
Using Radionode's power monitoring solution, you can enjoy practical benefits including:
● Aggregate accumulated power usage → Optimize work schedule
● Compare yesterday and today's power usage → Detect abnormal power consumption
● Comparison of power usage this month and last month → Cost management
● Provides comparison charts for equipment from different manufacturers → Integrated management of equipment performance
● Send emergency alarm when average usage exceeds → Realize preventive maintenance
● Providing various reports (daily/weekly/monthly/deviation management reports), etc. → Increased work efficiency
● Get started with power monitoring
Use Case 1.
Detection of equipment abnormalities and preventive maintenance through power monitoring

the beginning of the incident
Assistant Manager Kim works in the maintenance team of Manufacturer A. He recently announced that Radionode's UA20-DA power monitoring system was introduced using .
This makes it possible to monitor and analyze the power usage patterns of CNC machines in real time.
While analyzing the collected data, the power usagethis suddenly upsurgedid Email ReportReceived
Equipment inspection and preventive maintenance possible with UA20-D
Assistant Manager Kim noted that the machine's power consumption pattern was different from usual.
Typically, these machines used a consistent amount of power each day, with only small fluctuations in power usage when performing certain tasks.
But recent In the data Verify that power usage remains high even during non-working hoursI could.
This is a sign that the machine is consuming more energy than usual.It was.
Assistant Manager Kim records the work recently processed by the machine and Comparative analysis of power consumption data stored in Radionode365I did.
This confirmed that the spike in power consumption was not related to a specific task or load, but was caused by an issue with the machine itself.
As a result of the inspection, it is discovered that the machine's bearings are worn and the machine is under overload. Immediately replace the machine's bearings to ensure optimal performance. preventive maintenancewas carried out.
Use Case 2.
Efficient operation of refrigerated/frozen warehouses using power monitoring

The beginning of the story
B food distribution company located in Gyeonggi-do operates several refrigerators/freezers to store fresh ingredients.
The company adopted Radionode's power monitoring system to optimize energy usage and reduce electricity bills.
Manager Park works on the refrigerator/freezer management team at this distribution company. he is The power usage of certain freezers has increased significantly more than usual는 phone notificationI received it.
Cause analysis and problem solving using UA20-D
Manager Park Comparison with temperature data from other freezersI decided to give it a try.
Other normally operating freezers were effectively reducing internal temperatures while maintaining similar power usage.
Even though Freezer 15's power consumption increased, its internal temperature still did not reach the target temperature.
Through this data, Manager Park is convinced that there is a correlation between the freezer's power consumption and temperature.I did it. Manager Park decided to immediately inspect the freezer.
Internal temperature not dropping despite certain freezers using excessive powerThis was a clear sign that there was a problem with the cooling system.
Manager Park confirmed the problem with the freezer's refrigerant system and immediately repaired the refrigerant leak and refilled the insufficient refrigerant.
After repairs were completed, the freezer began to operate normally and the internal temperature remained stable at target levels.
Get started with power monitoring
▲ Click to go to the corresponding products page. ▲
If you adopt Radionode's power monitoring system, you will be able to detect abnormal power use early by analyzing the accumulated power consumption patterns of the machine.
By conducting preventive maintenance on your equipment through research, you could have prevented major breakdowns and saved 10% on your annual electric bills.
Now it's your turn to become the main character and write your success story. Start monitoring your power consumption with Radionode UA20-D.
-