Volatile organic compounds Oxygen carbon dioxide carbon monoxide Sulfur dioxide Nitrogen dioxide ammonia Hydrogen sulfide Hydrogen chloride Ethylene oxide Ethylene Atmospheric pressure Hydrogen nitrogen monoxide ozone 
RN172plus

Network is the default these days, RN172plus
Sensor data measured with UA, where do you want to send it?

Various USB type UA sensors can be attached and detached
UA1X: temperature and humidity, high temperature, low temperature, ultra low temperature
UA2X: 4-20mA, 0-20mA, 0-1V
· UA5X: Gas sensors (VOC, O2, CO2, CO, SO2, NO2, NH3, H2S, EO, H2, NO, O3, C2H4, C2H4O, ...)
· WiFi IEEE 802.11 b/g, WPA, WPA2
· Global integrated monitoring is possible with expanded WiFi channel support
· Data transmission via HTTP, MODBUS TCP, Telnet
· Front 2-channel LED display (brightness adjustable) / Built-in buzzer (selectable sound)
· Cloud-based text transmission, phone transmission, and email report transmission
· Radionode365 Cloud Serivce monitoring service support
· Tapaculo Lite PC type software support
· Model name: RN172WCD

True smart factory, IoT remote data logger
Volatile organic compounds Oxygen carbon dioxide carbon monoxide Sulfur dioxide Nitrogen dioxide ammonia Hydrogen sulfide Hydrogen chloride Ethylene oxide Ethylene Atmospheric pressure Hydrogen nitrogen monoxide ozone 

Where will the measured sensor data be sent?

  • Image area
    Remote control chart O, direct control chart O Free monitoring software to choose from

    Monitoring Software Troubleshooting!
    Radionode365 for Cloud Serivce and TP Lite for PC are available. Just sign in.

  • Image area
    IoT environment Various network protocols supported

    HTTP, MODBUS-TCP, Telnet
    The sensor data measured by the protocol is transmitted to the destination (server) in real time. It is very useful when building a system yourself.

  • Image area
    Improved network stability and compatibility Easy installation without the need for electricity/LAN construction

    Network stability and compatibility are improved by supporting more expanded WiFi channels. WiFi technology provides convenience in product installation.

for remote environmental monitoring New convenience, RN172plus

Prepared for IoT, remotely integrated management of measurement sensor data

  • Temperature, humidity, and various gases
    Supports UA sensors that can be used like cartridges

  • Eliminate remote data integration management cost!
    Radionode365 monitoring software

  • Device registration with a 4-digit code
    Automatic IP allocation

  • HTTP, MODBUS, TELNET data transmission, UDP broadcasting response
    Supports more expanded WiFi channels

  • Automatic backup in case of network loss
    Retry transmission when network recovery

  • Supports integration with Qlight warning lights for visual notifications
    Buzzer alarm provided for audible notification

  • Clear LCD screen both during the day and at night
    Four brightness options available

  • Provides a cover to protect the sensor
    A more stable power supply method

  • Easily identifiable
    Measuring sensor market sticker provided

How to use RN172plus remote data logger (WiFi)
RN172plus Remote Data Logger (WiFi) Features
  • Replaceable sensor support
    Replaceable sensor support

    The RN172WCD product is a data transmitter developed to easily build a sensor monitoring system using a general-purpose communication network. To support a variety of sensors, the sensor unit was developed in a USB format so that the user can select it.

  • Popular IoT, digital data transmission
    Popular IoT, digital data transmission

    The physical communication method supports WiFi. By supporting all Wi-Fi channels, compatibility with routers is improved and global integrated monitoring is easier. In addition, it supports various protocols such as MODBUS-TCP, HTTP, and Telnet, making it possible to build a sensor monitoring system very conveniently even in facilities with general-purpose networks.

  • Remote monitoring, software provided
    Remote monitoring, software provided

    It supports not only PC-type monitoring software (Tapaculo Lite) but also Cloud Serivce-based web software (Radionode365), and at the same time links software such as PLC, SCADA , and MES.

RN172plus Remote Data Logger (WiFi) How to use
  • Data transfer over Wi-Fi
    Data transfer over Wi-Fi

    Various software development and IoT industrial environment construction

    When a sensor is connected to a general transmitter, the measured value is output as current, so it is very difficult to process it in software, making it difficult to build an IoT environment in industrial sites. To solve this problem, we developed a sensor data transmitter that transmits data via Wi-Fi.

  • Support various communication protocols
    Support various communication protocols

    HTTP, MODBUS TCP, TELNET

    It supports MODBUS TCP PROTOCOL so that it can connect to PLC and Wi-Fi, which have been used continuously in industrial fields.
    It also supports HTTP PROTOCOL, the best interface for web monitoring, compatible with all web servers.

  • Supports more expanded WiFi channels
    Supports more expanded WiFi channels

    Improved network stability and compatibility

    RN172WCD, upgraded from the existing RN172WC, supports all Wi-Fi channels up to 12 and 13 channels, increasing compatibility with routers. Network stability has improved, enabling smooth communication even in environments where WiFi channels are set differently, making global integrated monitoring easier.

  • More stable power supply
    More stable power supply

    Power terminal using terminal block

    Power is supplied by connecting power directly to the terminal on the back of the product.
    Reduced space constraints when connecting multiple sensors to a device, increasing installation and sensor cartridge selection. And terminal blocks provide a more robust power connection, reducing the risk of power failure.

  • Provides a variety of options to choose from
    Provides a variety of options to choose from

    User-friendly setup support

    We provide a variety of options to enable you to use a monitoring instrument that is just right for each user and site.
    It provides four levels of screen brightness and three different buzzer alarm sounds. Additionally, firmware upgrades can be performed more conveniently by connecting directly to a PC.

  • smart data management program
    smart data management program

    Provides various software according to the usage environment

    We provide sensor data monitoring software such as ready-to-wear for free in Cloud Serivce and PC versions. Please request SDK if necessary.













  • 12V DC adapter
    12V DC adapter
    12V DC adapter
    12V DC adapter

    Order NumberAP-P1

    Product Specifications-DC 12V
    - Pin type
    - Line length: 3M

  • DAQ High Precision Temperature & Humidity Sensor
    DAQ High Precision Temperature & Humidity Sensor
    DAQ High Precision Temperature & Humidity Sensor
    DAQ High Precision Temperature & Humidity Sensor

    Order NumberUA10

    Product SpecificationsTemperature measurement range: -40~80℃
    Humidity measurement range: 5~95%RH

  • DAQ low temperature temperature sensor
    DAQ low temperature temperature sensor
    DAQ low temperature temperature sensor
    DAQ low temperature temperature sensor

    Order NumberUA11-T

    Product SpecificationsT-type thermocouple connection (up to 2 channels)
    Temperature measurement range: -100~300℃

  • DAQ high temperature temperature sensor
    DAQ high temperature temperature sensor
    DAQ high temperature temperature sensor
    DAQ high temperature temperature sensor

    Order NumberUA11-K

    Product SpecificationsK-type thermocouple connection (up to 2 channels)
    Temperature measurement range: 0~1,000℃

  • DAQ Cryogenic Temperature Sensor
    DAQ Cryogenic Temperature Sensor
    DAQ Cryogenic Temperature Sensor
    DAQ Cryogenic Temperature Sensor

    Order NumberUA13

    Product Specifications3-wire PT100 temperature sensor connection (max. 1 channel)
    Temperature measurement range: -200~300℃

  • DAQ 4-20mA Transmitter A
    DAQ 4-20mA Transmitter A
    DAQ 4-20mA Transmitter A
    DAQ 4-20mA Transmitter A

    Order NumberUA20-A

    Product SpecificationsAny 4-20mA output sensor can be connected (up to 2 channels)
    Built-in 100 Ohm 0.05% resistor
    3-point calibration certificate provided
    Calibration software provided

  • DAQ 4-20mA Transmitter B
    DAQ 4-20mA Transmitter B
    DAQ 4-20mA Transmitter B
    DAQ 4-20mA Transmitter B

    Order NumberUA20-B

    Product SpecificationsAny 4-20mA output sensor can be connected (max. 1 channel, 12V Loop power)
    Built-in 100 Ohm 0.05% resistor
    3-point calibration certificate provided
    Calibration software provided

  • DAQ 0-1V Transmitter
    DAQ 0-1V Transmitter
    DAQ 0-1V Transmitter
    DAQ 0-1V Transmitter

    Order NumberUA20-C

    Product SpecificationsAny 0-1V output sensor can be connected (up to 2 channels)
    1-5V signal available (connect 150 ohm resistor)
    3-point calibration certificate provided
    Calibration software provided

  • DAQ volatile organic compound air quality sensor
    DAQ volatile organic compound air quality sensor
    DAQ volatile organic compound air quality sensor
    DAQ volatile organic compound air quality sensor

    Order NumberUA50-VOC

    Product SpecificationsBuilt-in metal oxide gas sensor
    Total volatile organic compounds (tVOC) measurement range: 0 to 60,000 ppb
    Calculation range of expected value of atmospheric CO2 concentration: 400 to 1200 ppm
    For indoor air quality measurement

  • DAQ Oxygen Gas Sensor
    DAQ Oxygen Gas Sensor
    DAQ Oxygen Gas Sensor
    DAQ Oxygen Gas Sensor

    Order NumberUA52-O2

    Product SpecificationsBuilt-in optical gas sensor
    Oxygen measurement range: 0~25%
    Atmospheric pressure measurement range: 500~1200 mBar
    Temperature measurement range: -30 ~ 60℃
    O2 correction algorithm by atmospheric pressure
    Aircraft oxygen measurement, industrial safety

  • DAQ COXNUMX Gas Sensor
    DAQ COXNUMX Gas Sensor
    DAQ COXNUMX Gas Sensor
    DAQ COXNUMX Gas Sensor

    Order NumberUA52-CO2

    Product SpecificationsBuilt-in optical gas sensor
    Carbon dioxide measurement range: 0~20%
    Temperature measurement range: 0 ~ 50℃
    CO2 incubator monitoring, food storage, bio lab, building energy management, semiconductor production line, etc.

  • DAQ carbon monoxide gas sensor
    DAQ carbon monoxide gas sensor
    DAQ carbon monoxide gas sensor
    DAQ carbon monoxide gas sensor

    Order NumberUA53-CO

    Product SpecificationsBuilt-in film type gas sensor
    Carbon monoxide measurement range: 0~1000 ppm
    Long-life electrochemical sensor type
    For indoor air quality measurement

  • DAQ nitrogen dioxide gas sensor
    DAQ nitrogen dioxide gas sensor
    DAQ nitrogen dioxide gas sensor
    DAQ nitrogen dioxide gas sensor

    Order NumberUA53-NO2

    Product SpecificationsBuilt-in film type gas sensor
    Nitrogen dioxide measurement range: 0 to 5 ppm
    Long-life electrochemical sensor type
    for industrial safety

  • DAQ Sulfur Dioxide Gas Sensor
    DAQ Sulfur Dioxide Gas Sensor
    DAQ Sulfur Dioxide Gas Sensor
    DAQ Sulfur Dioxide Gas Sensor

    Order NumberUA53-SO2

    Product SpecificationsBuilt-in film type gas sensor
    Sulfur dioxide measurement range: 0~20 ppm
    Long-life electrochemical sensor type
    for industrial safety

  • DAQ Ammonia Gas Sensor A
    DAQ Ammonia Gas Sensor A
    DAQ Ammonia Gas Sensor A
    DAQ Ammonia Gas Sensor A

    Order NumberUA54-NH3-100

    Product SpecificationsBuilt-in electrochemical gas sensor
    Ammonia (NH3) measurement range: 0~100ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ Ammonia Gas Sensor B
    DAQ Ammonia Gas Sensor B
    DAQ Ammonia Gas Sensor B
    DAQ Ammonia Gas Sensor B

    Order NumberUA54-NH3-1000

    Product SpecificationsBuilt-in electrochemical gas sensor
    Ammonia (NH3) measurement range: 0~1000ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ Hydrogen Gas Sensor
    DAQ Hydrogen Gas Sensor
    DAQ Hydrogen Gas Sensor
    DAQ Hydrogen Gas Sensor

    Order NumberUA54-H2

    Product SpecificationsBuilt-in electrochemical gas sensor
    Hydrogen (H2) measurement range: 0~40000ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ Hydrogen Sulfide Gas Sensor
    DAQ Hydrogen Sulfide Gas Sensor
    DAQ Hydrogen Sulfide Gas Sensor
    DAQ Hydrogen Sulfide Gas Sensor

    Order NumberUA54-H2S

    Product SpecificationsBuilt-in electrochemical gas sensor
    Hydrogen sulfide (H2S) measurement range: 0-50ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ Hydrogen Chloride Gas Sensor
    DAQ Hydrogen Chloride Gas Sensor
    DAQ Hydrogen Chloride Gas Sensor
    DAQ Hydrogen Chloride Gas Sensor

    Order NumberUA54-HCL

    Product SpecificationsBuilt-in electrochemical gas sensor
    Hydrogen chloride (HCL) measurement range: 0 to 20 ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ Ethylene Gas Sensor A
    DAQ Ethylene Gas Sensor A
    DAQ Ethylene Gas Sensor A
    DAQ Ethylene Gas Sensor A

    Order NumberUA54-C2H4-10

    Product SpecificationsBuilt-in electrochemical gas sensor
    Ethylene (C2H4) measurement range: 0~10ppm
    Individual calibration certificate provided
    for industrial safety

  • DAQ ethylene gas sensor B
    DAQ ethylene gas sensor B
    DAQ ethylene gas sensor B
    DAQ ethylene gas sensor B

    Order NumberUA54-C2H4-100

    Product Specifications- Built-in electrochemical gas sensor
    - Ethylene (C2H4) measurement range: 0~100ppm
    - Individual calibration certificate provided
    - For industrial safety

  • DAQ Ethylene Oxide Gas Sensor
    DAQ Ethylene Oxide Gas Sensor
    DAQ Ethylene Oxide Gas Sensor
    DAQ Ethylene Oxide Gas Sensor

    Order NumberUA54-EO

    Product SpecificationsBuilt-in electrochemical gas sensor
    Ethylene oxide (EO) measurement range: 0 to 10 ppm
    Individual calibration certificate provided
    for industrial safety

  • UA59-CO2
    UA59-CO2

    Order NumberDAQ COXNUMX Gas Sensor

    Product SpecificationsBuilt-in NDIR type CO2 sensor (0~20%)
    Stainless steel exterior (cradle provided)
    Individual calibration certificate provided
    For outdoor air quality measurement

  • RG40 Zeroric to USB Film Cable
    RG40 Zeroric to USB Film Cable
    RG40 Zeroric to USB Film Cable

    Order NumberRG40 Zeroleak

    Product SpecificationsFilm Type USB Extension Cable
    Line Length: 50cm